The camera is well equipped for timecode synchronization with file timecode, which basically every editing software can read and process. Use one of our timecode generators Tentacle SYNC E or ORIGINAL timecode generator, TIMEBAR timecode display or our TRACK E audio recorder to supply your camera with timecode information. For more information about Tentacle syncing workflow with the Setup App, click here.
Proceed as follows:
- Set camera and Tentacle device to the same frame rate
- Synchronize your Tentacle device and set the Output Volume in the app to LINE or AUTO
- Set the camera menu:
- TC/Media > Timecode > Mode > Preset
- TC/Media > Timecode > Run > Free Run
- TC/Media > TC Display > Display Select > Timecode
- Set the selector switch TC IN/OUT > IN
- Connect your Tentacle device to the TC port on the back of the body
- The camera display with show EXT-LK once the camera is synced
Recommended cables
C08 Tentacle to BNC 90°-Timecode Cable
C06 Tentacle to BNC-Timecode Cable
Note:
We cannot guarantee the completeness or accuracy of information provided by third-party manufacturers, so we recommend that you contact these third-party manufacturers directly if you have any questions regarding their devices.